Netbackup Cannot Connect To Robotic Software Daemon
Ali well are you trying to do a inventory with the if yes then the issue can be resolved in two ways 1) uncheck the EMPTY MEDIA ACCESS PORT. Option and run the inventory or 2) apply the 5.0 and 5.1 devicemappings.txt file from the following link once applied it will allow the inventory to carry on even in case an empty media access port is detected. If its something else please do try the below mentioned steps Document ID: 264891 E-Mail this document to a colleague GENERAL ERROR: Robotic control daemon will not start. Details: Overview: Robotic control daemon will not start. Troubleshooting: Check the /usr/openv/volmgr/misc/ directory for any.lock. files.
Log Files: N/A Resolution: The main reason the robotic control daemon will not start, is that the robot is unavailable. Ensure that the robot is available and is configured with the correct device path. If the daemon will still not start, perform the following: 1. Shut down all the VERITAS NetBackup (tm) daemons: #/usr/openv/netbackup/bin/goodies/netbackup stop 2.
Nov 06, 2012 Try Restarting the Netbackup services, If it doesn't help please follow the below steps First turn off the firewalls temporarily.
Verify all NetBackup daemons are down by running the command: #/usr/openv/netbackup/bin/bpps -a Do not proceed until all NetBackup processes are down. (Remember to exit from the GUI interface.) 3.
Cd to /usr/openv/volmgr/misc/ 4. Delete the lock files (.lock.) that exist in this directory 5.
Netbackup Cannot Connect To Nb Java
Restart the NetBackup daemons: #/usr/openv/netbackup/bin/goodies/netbackup start The robotic control daemon should now start. Ciao Ankur Kumar.
Hello everyone, I am having trouble running the inventory on my robot. I am using NetBackup 6.0. Here is what I did; I opened the front of the tape library and took out the 2 trays and removed the cartriges from it.
Then I waited it ran its own inventory, got back to NetBackup, ran the inventory. I could tell from there that there were still some cartriges in some other slots.
So using robtest.exe I move the cartriges to the front slot and again removed them. I filled up the two front trays and now I can no longer run inventories. I get the following error message: Inventory failed: cannot connect to robotic software daemon (42) I can still access the robot using robtest. It's just that I can not move cartriges without know which slots are available. Folder lock 7.0 serial keys. Thanks in advance. RE: can't inventory my robot (MIS).